EX-601 · Power System‑II/Unsolved PYQ Paper
EX-601 Power System - II - Dec 2024 Question Paper
Under each question, How to answer lists the points an answer should cover, outlined by CampusPrep from the syllabus. Check the details against your textbook.
-
7 MarksaWhy the interconnected power system is necessary? Explain the problems associated with them.
How to answer
- Definition and need of interconnected power system - reliability, economy, reserve sharing
- Advantages: load sharing, reduced reserve, efficient use of resources
- Problems: fault level increase, stability, control complexity, cascading failures
- Protection, communication and coordination issues
-
7 MarksbWhat is deregulation in the power system? Explain its effect and how it can be overcome?
How to answer
- Definition of deregulation / unbundling: generation, transmission, distribution separation
- Effects: competition, pricing, open access, operational challenges
- Issues: congestion, market power, stability
- Remedies: regulatory framework, ISO, ancillary services
-
7 MarksaCompare different types of power flow studies used in the power system analysis.
How to answer
- List types: Gauss-Seidel, Newton-Raphson, Fast Decoupled Load Flow
- Basis of comparison: convergence, memory, iterations, accuracy
- Suitability for small vs large systems
- Summary table of merits and demerits
-
7 MarksbExplain Gauss-Seidel method of power flow analysis.
How to answer
- Power flow equations in $Y_{bus}$ form
- Iterative formula for $V_i^{k+1}$ with $P, Q$ specified
- Treatment of slack, PQ and PV buses and acceleration factor
- Steps, flowchart and convergence criteria
-
7 MarksaExplain why it is necessary to keep strict limits on the system frequency variations.
How to answer
- Relation of frequency to active power balance and synchronous speed
- Effects on turbines, generators, motors and clocks
- System stability, protection and grid code limits
- Need for load-frequency control
-
7 MarksbA 100 MVA 50 Hz turbo alternator operates at no load at 3000 rpm. A load of 25 MW is suddenly applied to the machine and the steam valves to the turbine commence to open after 0.6 secs due to the time lag in the governor sysetm. Assuming inertia constant H of 4.5 kW-sec per KVA of generator capacity, calculate the frequency to which the generated voltage drops before the steam flow commences to increase to meet the new load.
How to answer
- Stored kinetic energy $E = H \times S_{rated}$
- Energy deficit $= P_{load} \times t$ for 0.6 sec governor delay
- Swing equation to find rate of frequency fall / frequency drop
- Calculate $f = f_0 - \Delta f$ before steam flow increases
-
14 MarksDiscuss in detail about the generation and absorption of reactive power in power system components.
How to answer
- Reactive power generation by synchronous generators, capacitors, lines at light load
- Absorption by transformers, induction motors, lines at heavy load, reactors
- Role of $Q-V$ relationship and voltage control
- Compensation devices: synchronous condenser, SVC, shunt reactor/capacitor
-
7 MarksaState and derive the swing equation.
How to answer
- Definitions: power angle $\delta$, inertia $M$, $H$
- Derivation from rotor dynamics $M d^2\delta/dt^2 = P_m - P_e$
- Per-unit form $\frac{H}{\pi f} d^2\delta/dt^2 = P_m - P_e$
- Assumptions and significance for stability
-
7 MarksbA large generator is delivering 1.0 p.u. power to an initiate bus through a transmission network. The maximum power which can be transferred for pre-fault, during fault and post fault conditions are 1.8 p.u., 0.4 p.u. and 1.3 p.u. respectively find the critical clearing angle.
How to answer
- Initial angle $\delta_0 = \sin^{-1}(P_0/P_{max1})$
- Equal-area criterion formula for $\delta_c$
- Substitute $P_{max1}=1.8$, $P_{max2}=0.4$, $P_{max3}=1.3$ p.u.
- Compute critical clearing angle in degrees/radians
-
7 MarksaDiscuss the various methods of improving steady-state stability in power system.
How to answer
- Steady-state stability limit $P_{max}=EV/X$
- Methods: reduce $X$, increase $E,V$, series/shunt compensation
- High-speed excitation, bundled conductors, parallel lines
- Role of FACTS and load-frequency control
-
7 MarksbA 50 Hz, 4 pole turbo alternator rated 100 MVA, 11 kV has an inertia constant of 8 MJ/MVA. Find
- i)The energy stored in the rotor at synchronous speed.
- ii)The rotor acceleration if the mechanical input is suddenly raised to 80 MW for an electric load of 50 MW.
How to answer
- Stored energy $E = H \times MVA$ rating in MJ
- Accelerating power $P_a = P_m - P_e$
- Acceleration $\alpha = P_a/M$ and swing equation
- Compute $d^2\delta/dt^2$ and synchronous speed acceleration
-
7 MarksaExplain with the help of a block diagram the automatic voltage regulator of turbo generators.
How to answer
- Function of AVR: maintain terminal voltage
- Block diagram: exciter, amplifier, sensor, comparator, stabilizer
- Operation on load change and error signal
- Types: rotating vs static AVR
-
7 MarksbWhat is the need of the excitation system? Explain A.C. static excitation system.
How to answer
- Need: voltage control, stability, reactive power support
- Components of excitation system
- A.C. static excitation: thyristor bridge fed from auxiliary transformer
- Advantages: fast response, no rotating parts
-
14 MarksWrite short notes (any two)
- i)Types of buses used in the load flows study
- ii)Economic dispatch
- iii)Methods of improving transient stability
How to answer
- Two topics to be covered with definition, classification and key points
- Relevant formulas / diagrams for each (e.g., bus types table, equal-area, economic dispatch)
- Applications in power system operation
- Merits, limitations and conclusion
Go to where you left off?
Quick Add to Notes
Save questions, your own notes and screenshots into notes filed by unit. It takes a free account.
Create free accountHave an account? Log in